| Power: |
24 V DC/AC 50/60 Hz 12 VA |
|
Dimensions:
|
Electronics: H x W x D 284 x 157 x 65 mm Sensor: Ø 10 mm, lenght 250 mm
|
|
Measuring range:
|
0 - 9,999 ppm of CO volume. |
|
Display:
|
Backlighted graphical tft-display.
0 - 9,999 ppm of CO.
0 - 20.9 % of O2.
|
|
Accuracy (overall):
|
< ± 50 ppm @ < 250 ppm.
< ± 20 % @ > 250 ppm.
|
|
Gas temperature:
|
20 - 300 °C. |
|
Output signal:
|
4(0) - 20 mA free scalable
Galvanic isolation 300 V DC. |
| Input signal: |
4(0) - 20 mA free scaleable. |
| Serial data channel: |
RS 485 multinode channel and
RJ 45 TCP/IP (IP 54 sealed) connector |
|
Heat up time:
|
approx. 120 seconds. |
| Calibration: |
Sensors are factory calibrated.
Factory recalibrated sensors are offered either on request or on a subscriber basis. |
| Dive length: |
50 - 200 mm. |
| Fitting: |
15 mm hole in a cutting-ring fitting or a special guide tube. |
|
Probe connections:
|
Minimum 2,5 meter of cable between sensor and electronic unit ending in a 14 pole plug. |
| Configuration: |
CO2000ViewSet program on a PC used for all parameterisation, storage of calibration and configuration data. |
|
Web enabling (optional):
|
ARM 9 processor platform with Linux operation system. Standard RJ 45 TCP/IP connection, http, ftp and OPC servers plus a web based program update included. |